Skip to Content

GRIT Air Quality

Air Quality Sensor

Measure shop air and run filtration from real conditions.

GRIT Air Quality uses a Sensirion SEN55 environmental node to monitor particulate, humidity, temperature, VOC Index, and NOx Index. Choose the Standard configuration for a compatible air cleaner that already uses an iR/RF remote, or choose With RF Outlet to add remote switching to an air cleaner that does not have its own remote.

Key Features

  • Five-part sensing: Measures particulate, relative humidity, temperature, VOC Index, and NOx Index.
  • Configurable response: Set filtration thresholds and control behavior in the GRIT App.
  • Two configurations: Match an existing iR/RF remote or add the included RF outlet and handheld remote.
  • Local operation: Measurements, rules, and history stay on the GRIT Hub.
  • GRIT mesh: Communicates with the Hub or Hub Pro without relying on shop Wi-Fi at the sensor.
  • Status LED: An RGB indicator shows device status at a glance.

Specifications

  • Variants GA-AQ1001 Standard; GA-AQ1002 With RF Outlet
  • Sensor Sensirion SEN55 environmental node
  • Particulate measurements PM1.0, PM2.5, PM4.0, PM10
  • Environmental measurements Relative humidity and temperature
  • Air-quality indices VOC Index and NOx Index
  • Power 12V DC from a GRIT Power Bank or the included 120V wall adapter
  • Connectivity GRIT mesh to GRIT Hub or Hub Pro
  • Status RGB LED

In the Box

  • 1x GRIT Air Quality in the configuration selected at checkout
  • 1x 120V wall power adapter
  • 1x connection for 12V DC power from a GRIT Power Bank
  • 1x plug-in RF outlet with the With RF Outlet configuration
  • 1x handheld RF remote with battery with the With RF Outlet configuration

Compatibility

The Standard configuration works with compatible air cleaners that already use an iR/RF remote. The With RF Outlet configuration is for air cleaners without remote control, including many homemade filter systems. Not every remote-controlled air cleaner can be learned; contact GRIT before ordering if compatibility is uncertain.

Installation

Place the sensor in the shop breathing zone, connect the included wall adapter or compatible 12V DC power, and pair it with the Hub through the GRIT App. Learn the air cleaner remote commands for the Standard configuration, or plug the air cleaner into the included RF outlet for the With RF Outlet configuration, then set the operating thresholds.

*GRIT Hub or Hub Pro is required for device functionality.

Important Notes

Confirm remote compatibility before ordering the Standard configuration. Air Quality devices in GRIT Track systems are subject to a 25% software-upgrade charge; contact GRIT for details.

Air Quality readings and history

Automatic VOC profile

With the updated SEN55 firmware, GRIT Air Quality automatically applies the 720-hour VOC learning profile. There is no profile to select or opt-in setting. This longer learning timescale helps retain changes over days and weeks; it is not a 30-day wait before readings appear.

VOC Index remains the sensor's relative gas reading. The sensor also reports particle levels, temperature, humidity, and NOx Index. NOx Index is not a measured NO₂ concentration.

Estimated TVOC adds two gas equivalents in µg/m³: Mølhave equivalent and isobutylene equivalent. Both are calculated from VOC Index using Sensirion's method, with conversion before averaging. They are two interpretations of the same sensor signal, not two separately measured gases. Actual gas mixtures vary; these estimates are not absolute TVOC measurements.

The updated firmware checks that the VOC profile was applied before providing estimates. Older firmware or an unverified profile can still provide ordinary monitoring, but estimated TVOC may be unavailable.

Software availability

These screenshots show PM1250 Shop on pre-release test software: GRIT Hub 1.1.1186 on the develop channel, SEN55 sensor firmware 3.1.82, and the updated screen typography. They show actual readings captured on October 23, 2026. Feature availability depends on your Hub and sensor software and update channel. If these readings are missing, contact GRIT to confirm a compatible update for your system.

Read the Air Quality screen

Open your SEN55 Air Quality device in the GRIT App. The Device Monitoring card shows VOC Index alongside the two clearly labeled estimated TVOC values. The Air Quality Indicator and filtration threshold shown here are based on PM2.5.

PM1250 Shop Device Monitoring shows VOC Index 101, estimated TVOC Mølhave equivalent 247.8 µg/m³, and isobutylene equivalent 218.4 µg/m³.
Actual test Hub screen. VOC Index and estimated TVOC remain separate; the displayed values describe this capture, not recommended limits. Select the image to view it at full size.

Compare VOC and estimated TVOC history

  1. Choose View Monitoring, then History.
  2. Select a date range, then open Metrics.
  3. Select VOC Index, Estimated TVOC (Mølhave equivalent), and Estimated TVOC (isobutylene equivalent) to compare their recorded trends with PM2.5.

The chart keeps index values and µg/m³ on separate axes. Estimated TVOC history begins with compatible readings after the update; earlier VOC Index records are not retroactively converted. Newly collected readings can take up to five minutes to appear in saved history.

Air Quality History with selected VOC Index and both estimated TVOC equivalents, showing separate index and µg/m³ axes alongside PM2.5 and recorded filter events.
Recorded history from the same test sensor, zoomed into the update period. The two estimated TVOC traces use the concentration axis; VOC Index uses the index axis. Select the image to inspect the legend and chart at full size.

RESET Air and WELL

Sensirion's manufacturer guidance describes the gas-equivalent method and its limits. It does not establish RESET accreditation, WELL certification, or Works with WELL recognition for GRIT. For a building project, review the applicable program requirements, monitor eligibility, placement, reporting, and service plan.

Pricing is provided with your quote.
  • Air Quality Configuration
Air Quality Configuration Standard, With RF Outlet