Skip to Content

GRIT VFD Collector

Collector

Automate dust collectors running on a variable frequency drive.

The VFD Collector controls compatible industrial variable frequency drives through MODBUS RTU or a 0–10 V speed output and dry run contact. When a GRIT Trigger reports demand, the GRIT Hub sends the configured start, stop, or speed response for the active tool or zone. Existing VFD programming, safety interlocks, and site commissioning remain part of the installed system.

Estimate your VFD energy savings →

Key Features

  • MODBUS terminal: Removable connector for direct drive communication
  • Analog control: Sources a 0–10 V speed signal and provides a dry relay contact for the VFD run input
  • Power options: 120–240 V AC locking connector or 12–24 V DC center-positive barrel jack
  • Compatibility review: GRIT confirms the VFD make, model, control interface, and required command behavior before ordering
  • VHB mounting: Sticks inside the drive enclosure or nearby panel
  • Status LED: Red when connected and off; green when commanded on

Specifications

  • SKU GA-CO4000
  • Power Input 120–240 V AC or 12–24 V DC
  • DC Connector Center-positive barrel jack
  • Control Interfaces MODBUS RTU or 0–10 V speed output with dry run contact
  • MODBUS Terminal Removable
  • Mounting VHB tape (included)
  • Connectivity GRIT Mesh Network
  • Status RGB LED

In the Box

  • GRIT VFD Collector (GA-CO4000) and CT wire assembly
  • AC mains wire with bare or tinned leads
  • Low-voltage barrel connector with two push terminals
  • Green MODBUS, blue dry-relay, and black 0–10 V removable screw terminal plugs
  • VHB mounting tape

Compatibility

For compatible industrial dust collection systems with a supported MODBUS RTU or analog speed and digital run control path. It does not work with drives that lack either supported control path or installations where the required commands cannot be added while preserving existing safety controls and interlocks. Contact GRIT with the VFD manufacturer, model, and firmware before ordering.

Installation

Mount the device inside or near the drive enclosure and connect the control terminals for the selected MODBUS or analog mode. Supply 120–240 V AC to the locking AC connector or 12–24 V DC to the center-positive barrel jack. We recommend a licensed electrician for work inside a VFD enclosure. Pair the Collector with the GRIT Hub through the GRIT app.

Download the installation guide

*GRIT Hub is required for device functionality.

Dust Management
Pricing is provided with your quote.